PowerGridSourceSwitchgear, transformers, breakers, metering devices, and power distribution components for global buyers.
Up to 38 kV Front Cable Entry RMU
Ring Main Units

Up to 38 kV Front Cable Entry RMU | RFQ Sourcing Details

Ring Main Units · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryRing Main Units
Unitset
VoltageDetection System IEC 60255: Relays ​ IEC 62271-1: Common
Cable entryfront cable entry
specificationfor switchgear​ Additional technical documentation File download Aegis-36-technical-documentation-0223 Download Aegis-36-technical-documentation-0223.pdf
Current rating630 A
Ring main unitRMU
Voltage ratingUp to 36 kV
CategoryRing Main Units
AvailabilityInquiry required
Updated2026-06-11

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Ring Main Units. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

Aegis 36 is Lucy Electric’s latest product, originating from the very successful Aegis Plus product family. It is specially designed for secondary distribution networks, wind farms and photo-voltaic power stations with ratings up to 38 kV.

This range is available for both indoor and outdoor environments and offers high levels of reliability and operator safety. It is a compact, cost-effective and virtually maintenance free product.

With up to 630 A ratings, Aegis 36 has been developed for easy installation, operation and has a number of additional safety features. These include electrical and mechanical interlocking, a wide range of protection relays, cable, earth and test facility and much more.

Technical Details Economic full life cost Simple and safe installation Compact, suitable for mini-substations Suitable for indoor and outdoor applications 38 kV and 630 A ratings 3 and 4 functions in a single SF 6 insulated stainless steel enclosure Vacuum interrupter for circuit breakers Circuit breaker protection using a wide range of self-powered and auxiliary relays Motorisation for remote control Easy integration with SCADA networks Front access cable terminations, with DIN 400 type C bushings Compliance & Standards IEC : Circuit breaker​ IEC : Ring earth switch​ IEC : Ring switch​ IEC : Switch fuse​ IEC : Enclosure​ IEC : Voltage Presence Indication System​ IEC : Voltage Detection System IEC 60255: Relays ​ IEC 62271-1: Common specification for switchgear​ Additional technical documentation File download Aegis-36-technical-documentation-_0223 Download Aegis-36-technical-documentation-_0223.pdf

Up | Applications and Buyer Notes

Up is organized as a sourcing-ready Ring Main Units reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time questions befo

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Ring Main UnitsBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Voltage
Detection System IEC 60255: Relays ​ IEC 62271-1: CommonBased on visible page data; confirm exact value in the RFQ.
Cable entry
front cable entryBased on visible page data; confirm exact value in the RFQ.
specification
for switchgear​ Additional technical documentation File download Aegis-36-techniBased on visible page data; confirm exact value in the RFQ.
Current rating
630 ABased on visible page data; confirm exact value in the RFQ.
Ring main unit
RMUBased on visible page data; confirm exact value in the RFQ.
Voltage rating
Up to 36 kVBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryRing Main Units
Unitset
VoltageDetection System IEC 60255: Relays ​ IEC 62271-1: Common
Cable entryfront cable entry
specificationfor switchgear​ Additional technical documentation File download Aegis-36-technical-documentation-0223 Download Aegis-36-technical-documentation-0223.pdf
Current rating630 A
Ring main unitRMU
Voltage ratingUp to 36 kV
Distribution cabinetswitchgear

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource related product samples

Supplier profile

PowerGridSource Imported Supplier Pool
主营:Ring Main Units

View full profile >